Avtor/Urednik     Stroeven, Piet; Guo, Zhanqi
Naslov     Sampling concrete by too small elements; what should we do to get reliable information?
Tip     članek
Vir     Image Anal Stereol
Vol. in št.     Letnik 27, št. 3
Leto izdaje     2008
Obseg     str. 151-62
Jezik     eng
Abstrakt     Macroscopically heterogeneous materials like concrete are generally sampled by too small, i.e., subrepresentative elements that can be either of 2D (section images) or of 3D nature (specimens). Based on scientific notions, like stochastic heterogeneity and structure-sensitivity, which are at the very heart of materials science and stereology, the paper demonstrates biases in obtained information to be generally inevitable when derived from such sub-representative designs. Only reliable comparison studies can be performed under the condition that the linear size of samples and of minimum structural dimensions (resulting from observation resolution) are maintained as fixed proportions of the relevant representative area and/or volume elements. This is demonstrated by three case studies.
Deskriptorji     SAMPLE SIZE
MICROSCOPY
COMPUTER SIMULATION
PARTICLE SIZE
IMAGE PROCESSING, COMPUTER-ASSISTED