Avtor/Urednik     Bisdas, Sotiriosis; Rumboldt, Zoran; Šurlan, Katarina; Koh, Tong San; Deveikis, John; Spampinato, Maria Vittoria
Naslov     Perfusion CT measurements in healthy cervical spinal cord: feasibility and repeatability of the study as well as interchangeability of the perfusion estimates using two commercially available software packages
Tip     članek
Vir     Eur Radiol
Vol. in št.     Letnik 18, št. 10
Leto izdaje     2008
Obseg     str. 2321-8
Jezik     eng
Abstrakt     Our purpose was to examine the feasibility and reproducibility of perfusion CT studies in the cervical spinal cord and the interchangeability of the values obtained by two post-processing methods. The perfusion CT studies of 40 patients with neck tumours were post-processed using two software packages (Software-1: deconvolution-based analysis with adiabatic tissue homogeneity approach and Software-2: maximum-slope-model with Patlak analysis). Eight patients were examined twice for assessing the reproducibility of the technique. Two neuroradiologists separately post-processed the images with two arterial input functions (AIFs): (1) the internal carotid artery (ICA) and (2) the vertebral artery (VA). Maps of blood flow (F) in ml/min/100 g, blood volume (V) in ml/100 g, mean transit time (MTT) in seconds (s) and permeability (PS) in ml/min/100 g were generated. The mean F, V, MTT and PS (Software-1) with VA-AIF and ICA-AIF were 8.93, 1.12, 16.3, 1.88 and 8.57, 1.19, 16.85 and 1.94, respectively. The reproducibility of the techniques was satisfactory, while the V and MTT values (in Software-1) and the F and V values (in Software-2) were dependent on the site of the AIF (p >or= 0.03 and p=0.02, respectively). The interobserver agreement was very good. The significant differences in measurements for a single patient (%) using Software-1/Software-2 were +/-120%/110%, 90%/80%, 180% and 250%/130% for F, V, MTT and PS, respectively. Only F and PS values in the healthy tissue seemed to be interchangeable. Our results were in essential agreement with those derived by invasive measurements in animals. The cervical spine perfusion CT studies are feasible and reproducible. The present knowledge has to be validated with studies in spinal cord tumours in order to decide the usefulness of the perfusion CT in this field.
Deskriptorji     ALGORITHMS
BLOOD FLOW VELOCITY
SOFTWARE
ADULT
AGED
AGED, 80 AND OVER
FEASIBILITY STUDIES
RADIOGRAPHIC IMAGE INTERPRETATION, COMPUTER-ASSISTED
REPRODUCIBILITY OF RESULTS
SENSITIVITY AND SPECIFICITY
SPINAL CORD
TOMOGRAPHY, X-RAY COMPUTED