Author/Editor     Virgolin, Marco; Wang, Ziyuan; Balgobind, Brian; Dijk, van Irma; Wiersma, Jan; Kroon, Petra S.; Janssens, Geert O.; Herk, Marcel van; Hodgson, David C.; Zadravec-Zaletel, Lorna
Title     Surrogate-free machine learning-based organ dose reconstruction for pediatric abdominal radiotherapy
Type     članek
Vol. and No.     Letnik 65, št. 24
Publication year     2020
Volume     str. 245021-1-245021-9
ISSN     0031-9155 - Physics in medicine and biology
Language     eng
Abstract     To study radiotherapy-related adverse effects, detailed dose information (3D distribution) is needed for accurate dose-effect modeling. For childhood cancer survivors who underwent radiotherapy in the pre-CT era, only 2D radiographs were acquired, thus 3D dose distributions must be reconstructed from limited information. State-of-the-art methods achieve this by using 3D surrogate anatomies. These can however lack personalization and lead to coarse reconstructions. We present and validate a surrogate-free dose reconstruction method based on Machine Learning (ML). Abdominal planning CTs (n=142) of recently-treated childhood cancer patients were gathered, their organs at risk were segmented, and 300 artificial Wilms' tumor plans were sampled automatically. Each artificial plan was automatically emulated on the 142 CTs, resulting in 42,600 3D dose distributions from which dose-volume metrics were derived. Anatomical features were extracted from digitally reconstructed radiographs simulated from the CTs to resemble historical radiographs. Further, patient and radiotherapy plan features typically available from historical treatment records were collected. An evolutionary ML algorithm was then used to link features to dose-volume metrics. Besides 5-fold cross validation, a further evaluation was done on an independent dataset of five CTs each associated with two clinical plans. Cross-validation resulted in mean absolute errors %0.6 Gy for organs completely inside or outside the field. For organs positioned at the edge of the field, mean absolute errors %1.7 Gy for Dmean, %2.9 Gy for D2cc, and %13% for V5Gyand V10Gy, were obtained, without systematic bias. Similar results were found for the independent dataset. To conclude, we proposed a novel organ dose reconstruction method that uses ML models to predict dose-volume metric values given patient and plan features. Our approach is not only accurate, but also efficient, as the setup of a surrogate is no longer needed.
Keywords     rak v oroštvu
radioterapija
dozimetrija
pozne posledice
childhood cancer
radiotherapy
dosimetry
late adverse effects