Avtor/Urednik | Gregorič, Igor; Košir, Roman; Smart, Frank W; Messner, Gregory N; Patel, Vijay S; La Francesca, Saverio; Cervera, Roberto D; Frazier, OH | |
Naslov | Left ventricular assist device implantation in a patient with congenitally corrected transposition of the great arteries | |
Tip | članek | |
Vir | Tex Heart Inst J | |
Vol. in št. | Letnik 32, št. 4 | |
Leto izdaje | 2005 | |
Obseg | str. 567-9 | |
Jezik | eng | |
Abstrakt | Congenitally corrected transposition of the great arteries (ccTGA) ia a rare anomaly characterized by atrioventricular and ventriculo-arterial discordance and several other malformations that eventually lead to heart failure. We describe the case of a 53-year-old woman with ccTGA and aortic insufficiency who was a candidate for heart transplantation due to end-stage congestive heart failure. Her condition deteriorated before a suitable donor heart could be found; therefore, we placed a left ventricular assist device in the right (systemic) ventricle. Concomitantly, we removed the aortic (systemic) valve. The patient recovered uneventfully and was discharged from the hospital 2 months postoperatively. She underwent cardiac transplantation approximately 6 months later and continued to do well after 18 months. | |
Deskriptorji | HEART-ASSIST DEVICES TRANSPOSITION OF GREAT VESSELS HEART DEFECTS, CONGENITAL MIDDLE AGE |