Avtor/Urednik     Najdovski, L; Dragaš, AZ; Kotnik, V
Naslov     The killing activity of microwaves on some non-sporogenic and sporogenic medically important bacterial strains
Tip     članek
Vir     J Hosp Infect
Vol. in št.     Letnik 19
Leto izdaje     1991
Obseg     str. 239-47
Jezik     eng
Abstrakt     The killing activity of microwaves of 2450 MHz frequency and 325 W, 650 W and 1400 W power on some bacterial strains was investigated. Vegetative strains of Staphylococcus aureus, Streptococcus pyogenes Group A, F.scherichia coli, Pseudomonas aeruginosa and Enterococcusfaecalis and spores of Bacillus subtilir and Bacillis stearothermophilus in aqueous suspensions were exposed to 325 W and 650 W waves for different lengths of time. Enterococcusfaecalis and spores of B. subtalis and B. stearothermophilus were exposed additionally to 1400 W waves in aqueous and 'dried' suspensions. Vegetative bacteria were promptly killed in 5 min or less, E. faecalis being slightly more resistant. Bacterial spores were only killed in aqueous suspension when a 1400 W setting was used for 10 to 20 min. Bacterial spores adhering to the tube walls after the aqueous suspension was poured out were reduced in number. We assume that the conventional microwave ovens available on the market may be used for a high level of disinfection but not for sterilization, and only then if sufficient water is present.
Deskriptorji     BACTERIA
DISINFECTION
MICROWAVES
SPORES, BACTERIAL
STERILIZATION
DISINFECTION
DISINFECTION
EVALUATION STUDIES
STERILIZATION
TIME FACTORS