Avtor/Urednik     Sixel, KE; Podgoršak, EB; Souhami, L
Naslov     Cylindrical dose distributions in pseudodynamic rotation radiosurgery: an experimental study
Tip     članek
Vir     Med Phys
Vol. in št.     Letnik 20, št. 1
Leto izdaje     1993
Obseg     str. 163-70
Jezik     eng
Abstrakt     A linac-based radiosurgical technique is reported which produces cylindrical isodose distributions covering cylindrical targets of arbitrary orientations within the patient's head. The technique uses rectangular collimators and 4 degrees of freedom: gantry and couch rotation, as defined by a previously known dynamic rotation technique, collimator rotation, and collimator length adjustment. The relationship between the four parameters is derived and because of its complexity, the cylindrical dynamic rotation technique is introduced as a pseudodynamic technique. For cylindrical targets, the cylindrical pseudodynamic technique is comparison to the standard spherical technique produces considerable dose savings to healthy tissue surrounding the target and gives a similar or better dose fall-off outside the target.
Deskriptorji     RADIOSURGERY
BIOPHYSICS
BRAIN DISEASES
EVALUATION STUDIES
MODELS, STRUCTURAL
MODELS, THEORETICAL
RADIATION DOSAGE
RADIOSURGERY
ROTATION