Avtor/Urednik     Žganec, Mario; Lavrenčak, Jaka; Babić, Ankica; Us-Krašovec, Marija
Naslov     Detection of compact low-chromatin areas in cell nuclei images
Tip     članek
Vir     In: Cesnik B, McCray AT, Scherrer J-R, editors. MedInfo '98. Proceedings of the 9th world congress on medical informatics. Part 1, part 2; 1998; Seoul. Amsterdam: IOS Press,
Leto izdaje     1998
Obseg     str. 1017-21
Jezik     eng
Abstrakt     When analysing some DNA stained human cell nuclei using a light microscope or an quantitative image cytometer, compact low-chromatin areas (CLCA) can be observed. We are still not ceratin about the meaning and source of this phenomena. To enable the detection of CLCA by an image cytometer, a special image processing alghoritm has to be developed and new nuclear cell features have to be designed. The presented image processing alghoritm automatically detects CLCA in nucllei cell images taken from different tissues. The algorithm is composed of many basic image processing operations. The sequence of operations is determined by a priory knowledge about the properties of CLCA as a set of heuristic roles. The calculated CLCA features are CLCA area, perimeter, average intensity, compactnes and edge sharpness. The matching of the automatic CLCA detection and manual detection (performed by a biologist) was tested using 1400 cell nuclei. The results show a 83.4 match for the nuclei without CLCA and a 93.8% match for the cells with CLCA.
Deskriptorji     DNA
CELL NUCLEUS
CHROMATIN
IMAGE CYTOMETRY
IMAGE PROCESSING, COMPUTER-ASSISTED
LARYNGEAL NEOPLASMS
CELL LINE