Avtor/Urednik | Jarm, Tomaž; Steinberg, Fritz; Čemažar, Maja; Streffer, Christian; Serša, Gregor; Miklavčič, Damijan | |
Naslov | Correlation between results of different methods for measurement of blood perfusion and oxygenation changes in tumors after electrotherapy | |
Tip | članek | |
Vir | In: Jarm T, Kotnik T, Miklavčič D, editors. Proceedings including program of the 3rd international conference on bioelectromagnetism and 1st Slovenian-Croatian meeting on biomedical engineering in connection with COST 244bis 11th workshop on biomedical applications of electromagnetic fields and management commitee meeting; 2000 oct 8-12; Bled. Ljubljana: Faculty of electrical engineering, | |
Leto izdaje | 2000 | |
Obseg | str. 81-2 | |
Jezik | eng | |
Abstrakt | Different mechanisms are involved in antitumor effectiveness of electrotherapy by low level direct electric current (DC-ET). A strong evidence has been accumulated by means of different methods that when the electrodes are placed outside the experimental tumors in mice, DC-ET induces significant reduction of blood flow and oxygenation in tumors. The correlation between some of the results of different methods are presented here. | |
Deskriptorji | SARCOMA, EXPERIMENTAL ELECTROPORATION PERFUSION, REGIONAL MICE RUBIDIUM RADIOISOTOPES OXIMETRY SPECTROSCOPY, NEAR-INFRARED |