Author/Editor     Robida, Andrej; Pavčnik, Dušan
Title     Perforation of the heart in a newborn with critical valvar pulmonary stenosis during balloon valvoplasty
Type     članek
Source     Int J Cardiol
Vol. and No.     Letnik 26, št. 1
Publication year     1990
Volume     str. 111-2
Language     eng
Abstract     We describe the perforation of the right ventricular outflow tract with a 0.021 inch wire in a newborn infant with critical pulmonary valvar stenosis inan attempt to ballon dilatation of the pulmonary valve. The complication was diagnosed by contrast injection into the pericardium. The infant was followed with sector scan echocardiography and recovered completely from that injury. The dilatation was successfully repeated a few dazs later with the use of a soft tipped wire to cross the pulmonary valve.
Descriptors     HEART INJURIES
CARDIOMYOPATHY, HYPERTROPHIC
BALLOON DILATATION
PULMONARY SUBVALVULAR STENOSIS
WOUNDS, PENETRATING
INFANT, NEWBORN