Author/Editor     Benedičič, Mitja; Bernjak, Alan; Stefanovska, Aneta; Bošnjak, Roman
Title     Continuous wavelet transform of laser-Doppler signals from facial microcirculation reveals vasomotion asymmetry
Type     članek
Source     Microvasc Res
Vol. and No.     Letnik 74, št. 1
Publication year     2007
Volume     str. 45-50
Language     eng
Abstract     Facial laser Doppler flux (FLDF) consists of a mean value and complex oscillatory components called vasomotion. Vasomotion can be expressed as spectral amplitudes (SA) after the application of continuous wavelet transform. Vasomotion is influenced by cardiac activity (frequency interval I), respiration (interval II), intrinsic myogenic activity (interval III), neural mechanisms (interval IV) and endothelial mechanisms (intervals V and VI). Asymmetry of FLDF mean value was previously documented and hereby we present homogeneity assessment for FLDF vasomotion. Mean FLDF (p<0.001), total SA (p<0.001) and SA within frequency intervals I-VI were significantly higher in both cheeks compared to forehead. Total SA (p=0.009) and SA within frequency intervals I (p=0.041), II (p=0.005), III (p=0.009), IV (p=0.001) and V (p=0.036) were significantly higher in right than in left forehead. Human face is a heterogeneous microvascular region. Angiographic characteristics of deep horizontal sub-dermal plexus, endothelial and vascular smooth muscle cell heterogeneity, and plasticity of the microvasculature, autonomic asymmetry and facial neuropsychological asymmetry are possible causes of microvascular asymmetry. The origin and significance of microvascular imbalance need to be elucidated further.
Descriptors     LASER-DOPPLER FLOWMETRY
SIGNAL PROCESSING, COMPUTER-ASSISTED
ADULT
FACE
IMAGE INTERPRETATION, COMPUTER-ASSISTED
MICROCIRCULATION
MUSCLE, SMOOTH, VASCULAR
REGIONAL BLOOD FLOW
SKIN