Author/Editor | Tsai, Feng-Chun; Li, Han-Yan; Chou, An-Hsun; Huang, Huei-Chiun; Geršak, Borut | |
Title | Modified implant technique of perceval sutureless valve in congenital type 0 bicuspid valve stenosis | |
Type | članek | |
Vol. and No. | Letnik 111, št. 5 | |
Publication year | 2021 | |
Volume | str. e369-e371 | |
ISSN | 0003-4975 - The Annals of thoracic surgery | |
Language | eng | |
Abstract | The Perceval sutureless valve has gained in popularity for treating degenerative aortic valve stenosis but not for congenital type 0 bicuspid aortic valve owing to anatomic challenges. We modified implant techniques following the four principles of ECHO - an acronym for elasticity, circularity, height, and orientation - to prevent paravalvular leakage and - malposition. | |
Keywords | bicuspid valve stenosis sutureless valve modified implant technique stenoza bikuspidalne zaklopke brezšivna zaklopka prilagojena tehnika vsaditve |