Author/Editor     Ilić, R; Rant, J; Šutej, T
Title     Fast neutron radiography with a bubble damage polymer detector
Type     članek
Source     In: Fujine S, Kanda K, Matsumoto G-I, et al, editors. Neutron radiography. 3. Proceedings of the 3rd world conference; 1989 May 14-18; Osaka. Dordrecht: Kluwer Academic Publishers,
Publication year     1990
Volume     str. 299-304
Language     eng
Abstract     The applicability of Bd-100 bubble damage polymer detector (commercially available from Chalk River Nuclear Laboratories, Canada) to fast neutron radiography was investigated. The response of the detector was found to be - 3 x 10-5 bubbles cm-3/nf cm-2. Comparison with other type of detectors used in fast neutron radiography showed that BD-100 detector is the most sensitive image detection material in fast neutron radiography. A fast neutron fluence as low as 10 6 nf/cm2 seems to be sufficient to obtain an image with BD-100 detector.
Descriptors     RADIOGRAPHY
FAST NEUTRONS