Author/Editor     Čretnik, Andrej
Title     Čvrstost podkožnega prešitja Ahilove tetive po različnih metodah in pogojih trganja
Type     monografija
Place     Ljubljana
Publisher     Medicinska fakulteta
Publication year     1998
Volume     str. 23
Language     slo
Abstract     A study on thirty-six cadaveric Achilles tendons was undertaken to compare different Achilles tendon repairs. The strength of the repair and the gapping resistance were tested under different standardized experimental conditions. Each matched pair of cadaveric Achilles tendons was randomly repaired in the original Ma-Griffith configuration and in the original standard configuration and loaded to failure. Using a special equipment the force displacement curve was measured. Under different experimental conditions the original technique presented in the study provided significantly greater tensile strength and gapping resistance than the original Ma-Griffith repair configuration. The results of this study may be clinically relevant in terms of choice of the percutaneous method used for the repair of the ruptured Achilles tendon.
Descriptors     ACHILLES TENDON
RUPTURE
SUTURE TECHNIQUES
CADAVER
TENSILE STRENGTH