Author/Editor | Simončič, B; Kunzelmann, KH | |
Title | Trodimenzionalni optični čitalec za merjenje funkcionalne obrabe plombirnih materialov | |
Translated title | A three-dimensional optical scanner for measurement of functional wear of filling materials | |
Type | članek | |
Source | Zobozdrav Vestn | |
Vol. and No. | Letnik 54, št. 3-4 | |
Publication year | 1999 | |
Volume | str. 75-9 | |
Language | slo | |
Abstract | The article describes a three-dimensional optical scanner for measuring functional wear of filling materials. A well-defined protocol must be followed in preparing the samples to ensure that comparable measurements are obtained. The use of the scanner is demonstrated on one amalgam and one composite filling. A high resolution and accuracy place this method among the most reliable techniques for the evaluation of functional wear. | |
Descriptors | DENTAL RESTORATION, PERMANENT DENTAL AMALGAM IMAGE PROCESSING, COMPUTER-ASSISTED DENTAL RESTORATION WEAR |