Author/Editor     Šel, Davorka; Miklavčič, Damijan
Title     Numerical modelling of electric field in tissue with two needle electrodes: influence of needle modelling
Type     članek
Source     In: Jarm T, Kotnik T, Miklavčič D, editors. Proceedings including program of the 3rd international conference on bioelectromagnetism and 1st Slovenian-Croatian meeting on biomedical engineering in connection with COST 244bis 11th workshop on biomedical applications of electromagnetic fields and management commitee meeting; 2000 oct 8-12; Bled. Ljubljana: Faculty of electrical engineering,
Publication year     2000
Volume     str. 33-4
Language     eng
Abstract     Numerical modelling is inevitable approach when modelling electromagnetic problems of complex geometries. Many software products make numerical modelling easy, however several issues have to be considered in order to obtain satisfactory results. Some of those issues affecting the problem of numerical modelling of electric field in liver tissue are described. Numerical method used was finite element method. Special attention was paid to the modelling of needle electrodes and factors that influence the resulting electric field and reaction current in the case of in vivo electroporation. For that purpose the influence of shape of electrodes, their material, diameter and mesh density in region around electrodes was studied Results have shown which simplifications can be employed in modelling of needle electrodes.
Descriptors     COMPUTER SIMULATION
LIVER
ELECTROMAGNETIC FIELDS
ELECTRODES
ELECTROPORATION