Author/Editor     Pavčnik, Dušan; Uchida, Barry T; Timmermans, Hans A; Corless, Christhoper L; O'Hara, Michael; Toyota, Naoyuki; Moneta, Gregory L; Keller, Frederick S; Roesch, Josef
Title     Percutaneous bioprosthetic venous valve: a long-term study in sheep
Type     članek
Source     J Vasc Surg
Vol. and No.     Letnik 35, št. 3
Publication year     2002
Volume     str. 598-602
Language     eng
Abstract     A long-term evaluation of a new percutaneously placed bioprosthetic, bicuspid venous valve (BVV) consisting of a square stent and small intestinal submucosa (SIS) covering was performed in 12 sheep. Of 26 BVVs placed into the jugular veins, 25 exhibited good valve function on immediate venography and 22 on venograms obtained before the sheep were killed. Gross and histologic examination results demonstrated incorporation of remodeled and endothelialized SIS BVVs into the vein wall. Slight to moderate leaflet thickening was found mostly at their bases. Percutaneously placed SIS BVV is a promising one-way, competent valve that resists venous back-pressure while allowing forward flow.
Descriptors     BIOPROSTHESIS
BLOOD VESSEL PROSTHESIS
JUGULAR VEINS
SURGICAL INSTRUMENTS
EQUIPMENT SAFETY
FOLLOW-UP STUDIES
DISEASE MODELS, ANIMAL
PHLEBOGRAPHY
PROSTHESIS DESIGN
SHEEP
TIME FACTORS
TREATMENT OUTCOME
VASCULAR PATENCY